Viking Undercounter Ice Machine Code 3 Flashes: evaporator sensor open or shorted
Three flashes of the diagnostic LED on Viking Professional and Designer 15-inch undercounter ice machines, the VUIM, DUIM and DFIM 150 series such as the VUIM1531D and DFIM150D, report that the evaporator sensor is open or…
- Code
- 3 Flashes
- Appliance
- Ice Machine
- Brand
- Viking
- Warranty
- 30-day workmanship
What 3 Flashes means
Three flashes of the diagnostic LED on Viking Professional and Designer 15-inch undercounter ice machines, the VUIM, DUIM and DFIM 150 series such as the VUIM1531D and DFIM150D, report that the evaporator sensor is open or shorted. The control uses that sensor to judge freezing and harvest, so a bad reading can leave you with little ice, thin ice, or no ice cycle at all.
Common causes of 3 Flashes
- Evaporator sensor open
- Evaporator sensor shorted
- Loose sensor connector
1. Remove the ice, wipe the bin and check that the drain and water supply are fine. 2. Switch the ice machine off at its breaker for a few minutes, then restore power so it restarts. 3. Watch the LED when it starts up. 4. If three flashes return, call us. The evaporator is a sealed cold area, so leave it alone.
- The evaporator sensor is in the freezing section
- An open and a shorted sensor need to be told apart with a meter
- Written price first, and a 30-day warranty after the repair
Technical reference
- Code
- 3 Flashes
- Appliance
- Viking ice machine
- Maker documentation
- Viking owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Viking.
Other Ice Machine codes
What does the evaporator sensor do?
It senses the temperature of the evaporator plate, so the control knows when ice has formed and when to start the harvest. Without it, the timing is lost.
Why is ice thin or missing?
If the control cannot read the evaporator, it cannot time freezing and harvest properly, so the machine may stop or produce poor ice, or none at all.
Can I defrost it to fix this?
Defrosting does not repair a sensor reading. If the LED keeps blinking three times after a restart, the sensor or its connection needs to be tested by a technician.
Still seeing 3 Flashes?
A technician diagnoses it on site and gives you the price in writing before any work starts.