Specialty burners sit in tighter spaces and see more drips than the main burners, so they are the first to stop lighting.
Start with the basics
- Confirm the propane tank has fuel and the valve is open. Natural gas models need the shutoff open.
- Make sure the control knob is pushed in and turned fully to the light position.
- Check that the grill lid is open. Lighting with the lid closed is dangerous.
Cleaning the burner area
With the grill cool and the gas off, remove the grates and look at the burner. Grease, ash, and insects can block the ports. In our humid climate, small spiders and wasps like to nest in burner tubes and gas openings.
- Brush the burner surface with a soft brush.
- Clear each port with a soft wire or a straightened paper clip, working gently.
- Wipe the igniter electrode with a dry cloth. A greasy electrode will not spark well.
Try a match light only if the manual allows it, and never lean over the burner when you do. If you smell gas, move away, leave the house and call your gas utility from outside.
Signs you need service
If the electrode clicks but the burner stays dark, if the igniter makes no spark at all, or if the flame is weak and flickers, the igniter, module, or regulator may have failed. A regulator problem can affect every burner, so low flames across the grill should not be ignored.
Do not try to adjust gas fittings yourself. We use a leak test on the connections, check the spark system, and clear any blockages, then explain the findings before we begin.
See our outdoor grill repair page to book a visit. Work comes with a written price up front and a 30-day workmanship warranty.